Input | Model Capacity (VA/W) Phase Rated Voltage Voltage Range Frequency Range Power Factor Current THDi Bypass Voltage Range ECO Range Generator Input |
1500VA 1350W Single Phase & Ground 200/208/220/230/240VAC 110-300V* 40Hz-70Hz (Auto-Detect) > 0.98 <7% at 100% Non-Linear Load Bypass high voltage point : 230-264Vac (Setting on LCD, Default : 264Vac) Bypass Low voltage point : 176-220Vac (Setting on LCD, Default: 176Vac) Frequency Protection Range: +/-10% Same As The Bypass Support |
Output | Phase Rated Voltage Power Factor Voltage Regulation Frequency - Utility Mode - Battery Mode Crest Factor THD Wave Form |
Single Phase & Ground 200/208/220/230/240VAC 0.9 +/- 1% 50Hz or 60Hz (Synchronized to Mains) 50/60Hz +/- 0.02% Hz 3:1 < 3% with Linear Load, < 5% with non Linear Load Pure Sine Wave |
Efficiency | AC Mode (Full Load) Battery Mode (Full Load) ECO (Full Load) |
Up to 90% >88% >94% |
Battery | Voltage Capacity (Standard Unit) Backup Time Recharge Time to 90% Charging Battery Socket |
36Vdc 12V/9Ah Full load 5 min, 15-30 min (Depend on load), Estimated remaining time display on the LCD 4-5 Hours 1.4A Anderson Like PowerPole Modular Connectors |
Transfer Time | Utility to Battery; 0ms, Utility to Bypass <4ms | |
Protection | Overload - AC Mode - Batt. Mode - Bypass Mode Short Circuit Overheat Battery Low Self-Diagnostics EPO Battery Noise Suppression |
Load <100%-150%; 30S; Load >150%; 300ms then shutdown UPS completely Load <100%-150%; 30S; Load 150%; 300ms then shutdown UPS completely Load >130%; 60S then shutdown output Hold Whole System Line mode; Switch to Bypass; Battery Mode, shutdown UPS immediately Alarm and Switch off Upon Power On and Software Control Shutdown UPS immediately Advanced Battery Management Compiles with EN962040-2 |
Alarm | Audible & Visual | Line Failure, Battery Lw, Overload, Fault |
Display | Status LED Reading on the LCD |
Line mode/Battery/Bypass/Fault Load/Battery/Input/Output/Operating Mode information |
Physical | Dimension (WxHxD) mm. Weight (Kilogram) Input Connection Output Connection External Battery Connection |
440 x 86.5 x 460 16.5 IEC320 C14-10A Universal x 6 Anderson like PowerPole Modular connectors |
Communication Interface |
Smart RS232/USB Port Communication slot RJ 45 |
Support Windows Family, Linux, FreeDSB, etc. SNMP Card (independent to RS232) Built-in Power Surge, Lightning Protection Device |
Environment | Operating Temperature Storage Temperature Humidity Attitude Noise |
0 °C - 40 ° C -25 °C - +55 °C 0-90% non-condensing <1500 m. (derating while > 1500m) <50 dB (at 1 meter) |
Safety Conformance | CE |