ZC-MPIII
| Input | Model Capacity (VA/W) Phase Rated Voltage Voltage Range Frequency Range Power Factor Current THDi Bypass Voltage Range Generator Input |
1000VA 900W Single Phase & Ground 208/220/230/240Vac 110-300Vac (176-264Vac @100% load) 40Hz-70Hz (50/60Hz Auto-Sensing) ≥0.99 <6% at 100% non-linear load Bypass high voltage point : 230-264Vac (Setting on LCD, Default: 264Vac) Bypass low voltage point : 176-220Vac (Setting on LCD, Default: 176Vac) Support |
| Output | Phase Rated Voltage Power Factor Voltage Regulation Frequency - Line Mode - Battery Mode Crest Factor THD Wave Form |
Single Phase & Ground 208/220/230/240Vac 0.9 +/- 1% 46-54Hz or 56-64Hz (50Hz/60Hz +/- 0.1%) Hz 3:1 ≤ 3% with Linear Load ≤ 5% with non Linear Load Pure Sinewave |
| Efficiency | AC Mode ( Full Load ) Battery Mode ( Full Load ) ECO Mode ( Full Load ) |
88 % 85% >94% |
| Battery | Voltage Capacity (Standard Unit) Back up Time Recharge Time to 90% Charging current |
24Vdc 12V/9Ah 15-30 min (Depend on load), Long time depends on capacity of EBP 4 Hours recovery to 90% capacity (Typical) 1A |
| Transfer Time | Utility to Battery; 0ms, Utility to Bypass <4ms | |
| Protection | Overload - AC Mode - Batt. Mode Short Circuit Overheat Battery Low Self-Diagnostics EPO Battery Noise Suppression |
105%~125%: UPS transfer to bypass after 1minute when the utility is normal 125%~130%: UPS transfer to bypass after 30 seconds when the utility is normal >130%: UPS transfer to bypass immediately when the utility is normal 105%~125%: UPS after 1minute shut down; 125%~130%: UPS after 10 seconds shut down; >130%: UPS immediately shut down; Hold Whole System Line mode; Switch to Bypass; Battery Mode, shutdown UPS immediately Alarm and Switch off Upon Power On and Software Control Shutdown UPS immediately Advanced Battery Management Compiles with EN962040-2 |
| ALARM | Audible & Visual Reading on the LCD |
Line Failure, Battery Low, Overload, System Fault |
| Display | Status LED & LCD Reading on the LCD |
Input/Output Voltage, Frequency, Temperature, Load/battery Level, Charger, Load Capacity, Battery Voltage, Overload, ECO, Warning, Bypass, Battery, Inverter, ETC. |
| Physical | Weight (Kilogram) Input Connection Output Connection External Battery Connection |
9.3 IEC320 C14-10A Universal x 3 Anderson like PowerPole Modular connectors |
| Dimensions | WxDxH (mm.) | 144 x 293 x 209 |
| Communication Interface |
Smart RS232/USB Port Communication slot RJ 45 |
Support Windows 7 / 8 / 10 / 11, Windows Server 2019 etc. SNMP Card (independent to RS232) Built-in Power Surge, Lightning Protection Device |
| Environment | Operating Temperature Storage Temperature Humidity Attitude Noise |
0 °C - 40 ° C -25 °C - +55 °C 0-90% non-condensing <1500 m. (derating while > 1500m) <50 dB (at 1 meter) |
| Standards | Safty EMC ISO |
IEC/EN62040-1, IEC/EN62477-1 IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC6100-4-4 IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, IEC61000-2-2 ISO9001, ISO14001 |