| Input | Model Capacity (VA/W) Phase Rated Voltage Voltage Range Frequency Range Power Factor Current THDi Bypass Voltage Range ECO Range Generator Input |
3000VA 2700W Single Phase & Ground 208/220/230/240VAC 110~300Vac (176~264Vac @ 100% load) 40~70Hz (50/60Hz Auto-Sensing) >0.99 <6% at 100% non-linear load Bypass high voltage point : 230-264 Vac (Setting on LCD, Default: 264Vac) Bypass low voltage point : 176-220 Vac (Setting on LCD, Default: 176Vac) Same As The Bypass Support |
| Output | Phase Rated Voltage Power Factor Voltage Regulation Frequency - Utility Mode - Battery Mode Crest Factor THD Wave Form |
Single Phase & Ground 208/220/230/240VAC 0.9 +/- 1% 46~54Hz or 56~64Hz 50/60Hz ±0.1% 3:1 ≤ 3% with Linear Load ≤ 5% with non Linear Load Pure Sine Wave |
| Efficiency | AC Mode ( Full Load ) Battery Mode ( Full Load ) ECO Mode ( Full Load ) |
91% 88% >94% |
| Battery | Voltage Capacity (Standard Unit) Back up Time Recharge Time to 90% Charging current |
72Vdc 12V/9Ah 15-30 min (Depend on load), Long time depends on capacity of EBP 4 Hours recovery to 90% capacity (Typical) 1A |
| Transfer Time | Utility to Battery; 0ms, Utility to Bypass <4ms | |
| Protection | Overload - AC Mode - Batt. Mode Short Circuit Overheat Battery Low Self-Diagnostics EPO Battery Noise Suppression |
105%~125%: UPS transfer to bypass after 1minute when the utility is normal 125%~130%: UPS transfer to bypass after 30 seconds when the utility is normal >130%: UPS transfer to bypass immediately when the utility is normal 105%~125%: UPS after 1minute shut down; 125%~130%: UPS after 10 seconds shut down; >130%: UPS immediately shut down; Hold Whole System Line mode; Switch to Bypass; Battery Mode, shutdown UPS immediately Alarm and Switch off Upon Power On and Software Control Shutdown UPS immediately Advanced Battery Management Compiles with EN962040-2 |
| ALARM | Audible & Visual Reading on the LCD |
Line Failure, Battery Low, Overload, System Fault |
| Display | Status LED & LCD Reading on the LCD |
Input/Output Voltage, Frequency, Temperature, Load/battery Level, Charger, Load Capacity, Battery Voltage, Overload, ECO, Warning, Bypass, Battery, Inverter, ETC. |
| Physical | Weight (Kilogram) Input Connection Output Connection External Battery Connection |
24.5 IEC320 C20-16A Universal x 4, Terminal x 1 Anderson like PowerPole Modular connectors |
| Dimensions | WxDxH (mm.) | 191×460×337 |
| Communication Interface |
Smart RS232/USB Port Communication slot RJ 45 |
Support Windows 7 / 8 / 10 / 11, Windows Server 2019 etc. SNMP Card (independent to RS232) Built-in Power Surge, Lightning Protection Device |
| Environment | Operating Temperature Storage Temperature Humidity Attitude Noise |
0 °C - 40 ° C -25 °C - +55 °C 0-90% non-condensing <1500 m. (derating while > 1500m) <50 dB (at 1 meter) |
| Standards | Safty EMC ISO |
IEC/EN62040-1, IEC/EN60950-1 IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC6100-4-4 IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 ISO9001, ISO14001 |