True Online Double Conversion
TOWER DESIGN
High Frequency,
PF 1.0, LCD&LED, EPO Function
Programable Battery Voltage 384-480VDC, etc.
3 phase In, 3 phase Out
LCD Operation:
LCD control panel consists of LCD display board, LED and buttons, which displays
and controls these information including Utility, Inverter, Bypass, Load, Frequency,
Fault, Running, alarm information, function setting information.
ADVANCE PROTECTION FOR:
Small & medium datacenter
IT, Networking, Storage and Telecom
Infrastructure, Industrial and Medical
FEATURE:
Rack/Tower Convertible Design
Patented Mimic LCD Display May be Rotated by Simply Pushing Front Button
True Online Double Conversion with DSP Control
High Output Power Factor at PF.0.9
Charger/Fan Status on the LCD Display
Green Concept Design with Superior Input
Voltage Window for Energy Saving
Hot-Swappable Battery
3-level intelligent Charging Method
Support Generator Input
Efficiency up to 90%
Estimated Remaining Time displayed on the LCD.
Support Economic(ECO) Operation Mode
Cold Start
Power Shedding May Turn Off Uncritical Load in Battery Backup
Emergency Power Off (EPO)
Frequency Converter Mode Is Settable
CAPACITY | VA/Watts | 15KVA/15KW |
Input | Normal voltage Operating Voltage Range Operating frequency range Power factor Harmonic distortion (THDi) Bypass voltage range Generator input |
380/400/415VAC ,(3Ph+N+PE) 208-478vac 40Hz-70Hz 1.0 2%(100%Non-linear load) Max voltage:+15%(optional+10%,+25%) Min voltage:-45%(optional-20%,-30%)frequency protection range:+/-10% Support |
Output | Rated voltage Power factor Voltage Regulation Frequency Line Mode Frequency Batt Mode Crest Factor Harmonic distortion (THD) Efficiency & Wave Form |
380/400/415VAC,(3Ph+N+PE 1.0 +/-2% +/-1% 50/60(+/-0.1%) Hz 3:1 <2% with linear load, <5% with non linear load >93% at normal mode , Pure sinewave |
Battery | Battery Voltage Charge Current Maximum |
Optional voltage : 384/408/432/456/480VDC 12A |
System feature | Transfer time Overload line mode Overload batt. mode Overload bypass mode Short Circuit Overheat Low battery voltage Selfdiagnostics Epo (option) Batterry Noise Suppression Audible & Visual Status LED & LCD display Reading on the LCD display Communication Interface |
0 MS. Lode <110% last 60min, <125%: last 10min, <150%: last1min, >150% shutdown UPS immediately Lode <110% last 10min, <125%: last 5min, <150%: last 5s, >150% shutdown UPS immediately Breaker 350A Hold Whold system Line mode: switch to bypass, backup mode : shutdown UPS immediately Alarm and switch off Upon power on and sofware control Shutdown UPS immediately Advanced battery management Complies with EN62040-2 Line failure , Battery low, overload, System fault Line mode, bypass mode, battery low, battery bad, overload & UPS fault Input voltage, output valtage, input frequency, output frequency, load percentage, battery voltage,Inner temp. RS230,RS485,parallel, intelligent slot, slot, relay card (optional), SNMP card (optional) |
Environmental | Operating tenperature Storage Temperature Humidity range Attitude |
0 C - 40C -25 C - 55 C 0 - 95% (NON condensing) < 1500m |
Physical | Dimension D X W X H (MM) Net Weight (KG) |
828 x 250 x 868 170/63 |
Standards | Safety EMC |
IEC/EN62040-1;IEC/EN60950-1 IEC/EN62040-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4;IEC61000-4-5;IEC61000-4-6;IEC61000-4-8 |