| Input | Model Capacity (VA/W) Phase Rated Voltage Voltage Range Frequency Range Power Factor Current THDi Bypass Voltage Range ECO Range Generator Input |
3000VA 2700W Single Phase & Ground 200/208/220/230/240VAC 140-290V* 40Hz-70Hz (Auto-Detect) 0.99 @100% load (Nominal Input Voltage) <6% at 100% Non-Linear Load Bypass high voltage point : 230-264Vac (Setting on LCD, Default: 264Vac) Bypass high voltage point : 170-220Vac (Setting on LCD, Default: 170Vac) Same as The Bypass Support |
| Output | Phase Rated Voltage Power Factor Voltage Regulation Frequency - Utility Mode - Battery Mode Crest Factor THD Wave Form |
Single Phase & Ground 200/208/220/230/240VAC 0.9 +/- 1% (Battery Mode) 50Hz or 60Hz (Synchronized to Mains) 50Hz-60Hz +/- 0.02% Hz 3:1 < 3% with Linear Load < 5% with non Linear Load Pure Sine Wave |
| Efficiency | AC Mode ( Full Load ) Battery Mode ( Full Load ) ECO Mode ( Full Load ) |
Up to 90% >88% >94% |
| Battery | Voltage Capacity (Standard Unit) Back up Time Recharge Time Charging Current - Standard - Special |
72Vdc 12V/9Ah Full load 5 min, 15-30 min ( Depend on load), Lone time depends on the capacity of EBP 4 Hours recover to 90% capacity (Typical) 1 A 12A |
| Transfer Time | Utility to Battery; Zero (0ms), Utility to Bypass <4ms | |
| Protection | Overload - AC Mode - Batt. Mode - Bypass Mode Short Circuit Overheat Battery Low Self-Diagnostics EPO Battery Noise Suppression |
105%-110%: UPS shuts down after 10 mins, 110%-130%: UPS shuts down after 1 mins, >130%: UPS shuts down after 3 seconds 10A (Input breaker) Hold Whole System Line mode; Switch to Bypass; Battery Mode; shutdown UPS immediately Alarm and Switch off Upon Power On and Software Control Shutdown UPS immediately Advanced Battery Management Compiles with EN962040-2 |
| Alarm | Audible & Visual | Line Failure, Battery Low, Overload, System Fault |
| Display | LCD & LED | Input/Output Voltage, Frequency, Teperature, Load/battery Level, Charger, Load Capacity, Battery Voltage, Overload, ECO, Warning, Bypass, Battery, Inverter, ect. |
| Physical | Dimnsion (WxHxD) mm. Weight (Kilogram) External Battery Connection |
191 x 337 x 460 27.6 Anderson like PowerPole Modular connectors |
| Communication Interface |
RS232/USB Port Communication slot RJ 45 |
Support Windows Family, Linux, FreeDSB, etc. SNMP Card / Relay Card *Optional Built-in Power Surge, Lightning Protection Device |
| Environment | Operating Temperature Storage Temperature Humidity Attitude Noise |
0 °C - 40 ° C -25 °C - 55 °C 0-90% non-condensing <1500 m. (derating while > 1500m) <50 dB (at 1 meter) |
| Standards | Safety EMC ISO |
IEC/EN62040-1, IEC/EN60950-1 IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 ISO9001, ISO14001 |